Tel: 0118 933 2533 Fax: 0118 933 1224 email: sales@teelectronics.co.uk |
|
THE JACKDAW THE DEVIL'S HIGHWAY MORTIMER WEST END READING, BERKS RG7 2AD |
|
PSUs |
|
TE1206 SMPSU for GEC Avionics, 1982
3 phase 115V 400Hz input with 5V 60A output and a 150ms hold-up time. This PSU was used on the ill-fated Nimrod project; the hold-up time was required because large hydraulic pumps caused the 115V supply to collapse. Cooling was mainly by contact through the machined aluminium base plate.
|
|
|
|
TE1705 3U RACK PSU for Geoservices, Paris; 1987
Simple 230V AC in, +/-18V dc out linear Power Supply. Also provides multi-rail monitoring for back-plane plus system power control.
Front Panel silk-screening includes the Geoservice Logo.
Still in production as part of a Geoservice custom Data Acquisition System for oil exploration.
|
|
TE1103 Triple OP Linear PSU for Measurement Systems Ltd, 1981 5V 2A (later 3A) and +/-12V 0.6A tot Linear PSU in Bench and rack formats. Used novel "see-saw" current limit on +/- outputs which allowed the limit on one rail to increase if the other was lightly loaded.
|
|
|
TE2924 MULTI OUTPUT PSU for ADVANCED SYSTEMS, 1999
5V 6A, +/-12V 1A, 20V 2A for powering a Riva Compact PC plus high speed ticket printer. The top of the PSU case has locating wells for the printer. The carrying handle doubles as a paper guide. Used in compact tote kiosks as part of an Advanced Totes system.
|
last updated 8th September 2001
Copyright©
2001,
All rights reserved.